兔的血清淀粉樣蛋白A(SAA)檢測試劑盒使用說明書

來源:上海武昊經(jīng)貿有限公司   2013年10月29日 22:00  

[ INTENDED USE ]

The Chemiluminescent Immunoassay kit is designed for the in vitro sensitive quantitative measurement of SAA in rabbit serum, plasma and other biological fluids.

[ REAGENTS AND MATERIALS PROVIDED ]

Reagents

Quantity

Reagents

Quantity

Pre-coated, ready to use 96-well strip plate

1

Plate sealer for 96 wells

4

Standard (lyophilized)

2

Standard Diluent

1×20mL

Detection Reagent A (green)

1×120μL

Assay Diluent A (2 × concentrate)

1×6mL

Detection Reagent B (red)

1×120μL

Assay Diluent B (2 × concentrate)

1×6mL

Substrate A

1×10mL

Substrate B

1×2mL

Wash Buffer (30 × concentrate)

1×20mL

Instruction manual

1

[ MATERIALS REQUIRED BUT NOT SUPPLIED ]

1. Luminometer capable of reading 96-well microplates with the following parameters:

  lag time 30.0secs; read time 1.0 sec/well .

2. Precision single or multi-channel pipettes and pipette tips with disposable tips.

3. Eppendorf Tubes for diluting samples.

4. Deionized or distilled water.

5. Absorbent paper for blotting the microtiter plate.

6. Container for Wash Solution

[ STORAGE OF THE KITS ]

1. For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20oC upon receipt while the others should be at 4 oC.

2. For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.

Note:

It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.

[ SAMPLE COLLECTION AND STORAGE ]

Serum - Use a serum separator tube and allow samples to clot for two hours at room temperature or overnight at 4oC before centrifugation for 20 minutes at approximay 1000×g. Assay freshly prepared serum immediay or store samples in aliquot at -20oC or -80oC for later use. Avoid repeated freeze/thaw cycles.

Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000×g at 2 - 8oC within 30 minutes of collection. Remove plasma and assay immediay or store samples in aliquot at -20oC or -80oC for later use. Avoid repeated freeze/thaw cycles.

Other biological fluids - Centrifuge samples for 20 minutes at 1000×g. Remove particulates and assay immediay or store samples in aliquot at -20oC or -80oC for later use. Avoid repeated freeze/thaw cycles.

Note:

1.  Samples to be used within 5 days may be stored at 4oC, otherwise samples must be stored at -20oC (≤1 month) or -80oC (≤2 months) to avoid loss of bioactivity and contamination.

2.  Sample hemolysis will influence the result, so hemolytic specimen can not be detected.

3.  When performing the assay, bring samples to room temperature.

[ TEST PRINCIPLE ]

The microtiter plate provided in this kit has been pre-coated with an antibody specific to SAA. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for SAA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the SAA level in the sample or standard.

[ ASSAY PROCEDURE SUMMARY ]

   1. Prepare all reagents, samples and standards;

   2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;

   3. Add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;

   4. Aspirate and wash 3 times;

   5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;

   6. Aspirate and wash 5 times;

   7. Add 100μL Substrate Solution. Incubate 5-10 minutes at 37oC;

8. Read RLU value immediay.

[ CALCULATION OF RESULTS ]

Average the duplicate readings for each standard, control, and samples and subtract the average zero standard relative light unit (RLU). Create a standard curve on log-log graph paper, with SAA concentration on the y-axis and the RLU value on the x-axis. Draw the best fit straight line through the standard points and it can be determined by regression analysis. Using some plot software, such as curve expert 1.30, is also recommended. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

[ SENSITIVITY ]

The minimum detectable dose of rabbit SAA is typically less than 10. 2ng/mL.

The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean RLU value of 20 replicates of the zero standard added by their three standard deviations.

[ SPECIFICITY ]

This assay has high sensitivity and excellent specificity for detection of rabbit SAA.

No significant cross-reactivity or interference between rabbit SAA and analogues was observed.

Note:

Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between rabbit SAA and all the analogues, therefore, cross reaction may still exist.

[ RECOVERY ]

Matrices listed below were spiked with certain level of recombinant rabbit SAA and the recovery rates were calculated by comparing the measured value to the expected amount of SAA in samples.

Matrix

Recovery range (%)

Average(%)

rabbit serum(n=5)

90-98

94

rabbit EDTA plasma(n=5)

94-107

102

rabbit heparin plasma(n=5)

90-105

98

[ LINEARITY ]

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of rabbit SAA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample

1:2

1:4

1:8

1:16

rabbit serum(n=5)

88-102%

92-105%

85-98%

90-98%

rabbit EDTA plasma(n=5)

81-92%

91-107%

94-105%

87-97%

rabbit heparin plasma(n=5)

86-94%

90-97%

87-97%

92-101%

[ PRECISION ]

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level rabbit SAA were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level rabbit SAA were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

[ STABILITY ]

The stability of CLIA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37oC for 3 days, and compare RLU values of the kit kept at 37oC with that of at recommended temperature. (referring from China Biological Products Standard, which was calculated by the Arrhenius equation. For CLIA kit, 1 day storage at 37oC can be considered as 2 months at 4oC, which means 3 days at 37oC equaling 6 months at 4oC).

Note:

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

flb <h]s ??s > Centrifuge samples for 20 minutes at 1000×g. Remove particulates and assay immediay or store samples in aliquot at -20oC or -80oC for later use. Avoid repeated freeze/thaw cycles.

 

Note:

1.  Samples to be used within 5 days may be stored at 4oC, otherwise samples must be stored at -20oC (≤1 month) or -80oC (≤2 months) to avoid loss of bioactivity and contamination.

2.  Sample hemolysis will influence the result, so hemolytic specimen can not be detected.

3.  When performing the assay, bring samples to room temperature.

免責聲明

  • 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡有限公司-化工儀器網(wǎng)合法擁有版權或有權使用的作品,未經(jīng)本網(wǎng)授權不得轉載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權使用作品的,應在授權范圍內使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關法律責任。
  • 本網(wǎng)轉載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網(wǎng)站或個人從本網(wǎng)轉載時,必須保留本網(wǎng)注明的作品第一來源,并自負版權等法律責任。
  • 如涉及作品內容、版權等問題,請在作品發(fā)表之日起一周內與本網(wǎng)聯(lián)系,否則視為放棄相關權利。
企業(yè)未開通此功能
詳詢客服 : 0571-87858618
类乌齐县| 长治市| 廉江市| 荔浦县| 柯坪县| 哈巴河县| 湖州市| 曲阳县| 团风县| 郑州市| 湾仔区| 广昌县| 四川省| 涟水县| 中卫市| 安远县| 赤水市| 康乐县| 玛曲县| 曲沃县| 临猗县| 延寿县| 灯塔市| 临西县| 宜君县| 平昌县| 中方县| 惠东县| 射洪县| 海盐县| 汉阴县| 乐昌市| 安达市| 汉中市| 青田县| 东源县| 辛集市| 汉寿县| 平利县| 磴口县| 永春县|