鮑米勒伺服驅(qū)動(dòng)器維修服務(wù):719:Timeout during motor identification電機(jī)識(shí)別超時(shí)。Error during identification of motor parameters. The maximum permitted phase voltage (= 80 V) was exceeded during the resistance measurement.識(shí)別電機(jī)參數(shù)時(shí)出錯(cuò)。在電阻測(cè)量過(guò)程中,超過(guò)了每個(gè)允許相的最大電壓(=80V)。
Possible cause: 原因:
Incorrect motor nominal current setting in Parameter 107.09.
參數(shù)107.09中的電機(jī)標(biāo)稱電流設(shè)置不正確。
Effect: Output voltage set to ZERO to protect the motor. An additional drive block occurs with standard error response.
效果:輸出電壓設(shè)置為零,以保護(hù)電機(jī)。附加的驅(qū)動(dòng)器塊出現(xiàn)標(biāo)準(zhǔn)錯(cuò)誤響應(yīng)。
Resetting after error elimination: 錯(cuò)誤消除后重置:
Error reset is possible. Timeout (45 seconds) with R measurement with motor parameter identification, such as due to error during current / voltage measurement or normalization or limit value.錯(cuò)誤重置是可能的。電機(jī)參數(shù)識(shí)別的R測(cè)量超時(shí)(45秒),例如由于電流/電壓測(cè)量或標(biāo)準(zhǔn)化或限值過(guò)程中的錯(cuò)誤。