預(yù)裝彈簧包裝可控制逃逸排放和泄漏。
無閥蓋閥組件消除了因折斷而造成的安全隱患
或未擰緊的引擎蓋。
選擇下面的通用型號鏈接以查看詳細(xì)的產(chǎn)品規(guī)格,
產(chǎn)品外形圖,并以交互方式建立您的產(chǎn)品型號。

PRGM7-TT-SS-AF1F2

 

PRGM7-TV-SS-F2F2-#6-8-CV

 

PRGM7-TV-SS-AF1F2-#4-8BGP3FU-T-SS-3-valve monifold-CV-F2

 

PRGM6-TV-SS-F2F2-#6-8B-CV-MB

 

PRGM7-TV-SS-AF1F2-#6-8BGP3FU-T-SS-3-valve monifold-CV-F2

 

 

 

d-a-mfg / PRGM7-TV-SS-F2F2-#2-5  

d-a-mfg / PRGM7-TV-SS-AF1F2-#2 -8   

d-a-mfg / PRGM7-TV-SS-AF1F2-#6-8  

d-a-mfg / PRGM7-TV-SS-AF1F2#6-5-GP3FU-CV   

d-a-mfg / prgm7-tv-ss-af1f2-#6  

d-a-mfg / PRGM7-TV-SS-F2F2-#2-5   

d-a-mfg / PRGM7-TT-SS-AF1F2-#2-GP3FU  

d-a-mfg / PRGM6-TT-SS-F2F2-#6   

d-a-mfg / PRGM6-TT-SS-AF1F2-#6-CV 氣動(dòng)傳動(dòng)閥 Pneumatic transmission valve       

d-a-mfg / D70AAA05PZ  

d-a-mfg / PRGM6-TT-SS-F1F2-#6  

d-a-mfg / PRGM7-T-SS-AF1F2-#6   

d-a-mfg / PRGM7-TT-SS-AF1F2-#6-CV 氣動(dòng)傳動(dòng)閥 Pneumatic transmission valve       

d-a-mfg / PRGM7-TV-SS-AF1F2-#6   

d-a-mfg / PRGM7-TV-SS-AF1F2-#8-8-GP3FU-CV  

d-a-mfg / PRGM6-TT-SS-F2F2-#6-7-CV  

d-a-mfg / D70AAA06PZ  

d-a-mfg / PRGM7-TT-SS-AF1F2-#6-GP3FU  

d-a-mfg / PRGM7-TV-SS-AF1F2-#2  

d-a-mfg / 2 PRGM7-TT-SS-AF1F2-#6-GP3FU  

d-a-mfg / PRGM6-TT-SS-F2F2-#6-5-CV-MB

 

WERUCON MDB-1/1--DC24V-1,0-A  

WERUCON SLD-R-5,2-H70-3,0-K L002-00002 

Designed to be the safest, most reliable and dependable instrument manifold or valve.
Select the Safti-Fold model links below to view detailed product specifications,
product outline drawings, and to interactively build your product model numbers.

Differential Pressure Manifolds
Manifold
Functions
PictureModel
Number
Connections
Instrument x Process
Remote Mount
3SF3ATSF3AT1/2" FNPT x 1/2" FNPT
Transmount
3SF3TC
SF3TC shown
SF3T4CFlanged x Tube
SF3TCFlanged x 1/2" FNPT
SF3FCFlanged x Flanged
Unimount
3SF3TU
SF3TU shown
SF3TUFlanged x 1/2" FNPT
SF3FUFlanged x Flanged
5SF5BUSF5BUFlanged x Flanged

Top

Static Pressure Manifolds
Manifold
Functions
PictureModel
Number
Connections
Instrument x Process
Unimount
2SF2PTMUSF2PTMUFlanged x 1/2" FNPT
Remote Mount
3SF2PTMSF2PTM1/2" FNPT x 1/2" FNPT

Top

Gauge and Block Valves
PictureModel
Number
Connections
InletOutlet
SFPGSFPG1/2" or 3/4"
MNPT
(3) 1/2" FNPT
SFBKSFBKVarious*Various*

Shown Here: PRGM7 mounted to a GP3FU Manifold
Modes of Operation
 

PURGE ON

Shown with the Function Selector Handle * turned to "PURGE ON" and both service valves turned to "NORMAL". This is the NORMAL run mode.
 

 

TEST

Shown with the Function Selector Handle * turned to "PURGE ON" and the left service valve turned to "TEST".
When either of the service valves are turned to "TEST", the discharge of that flow cartridge is blocked downstream of the pressure indicator (PI). This "PI" was indicating process pressure, but it will now increase to indicate the purge inlet pressure as flow continues through the flow cartridge. The rate of pressure rise is a direct indication of flow rate through the cartridge; thus, serving as a good, positive indicator of two things: 1) Is the cartridge plugged? and 2) Is the purge and process pressure differential large enough?
If a more accurate indication of the flow rate is desired, open the vent valve to bring the (PI) down to zero pressure. Then close the vent valve and time how long it takes the flow cartridge to bring the (PI) back up to purge line pressure. Since the purge header pressure is constant throughout the plant, this recharge time should be fairly constant.
This vent and recharge procedure can also be used to try and clear a restricted flow cartridge. If it does not clear, then dial "PURGE OFF", vent off the pressure, and replace the cartridge.
 

 

PURGE OFF & TEST

Shown with the Function Selector Handle * turned to "PURGE OFF" and both service valves turned to "TEST".
This is the mode used to remove or replace a flow cartridge or pressure gauge. Use the vent system to bleed off ALL pressure prior to removing a cartridge or gauge.
 

 

FAST PURGE

Shown with the Function Selector Handle * turned to "FAST PURGE" on the left side. Mirror image results are obtained by dialing to the right side.
This mode is used to blast the tap lines clean. It is necessary to go on manual control before doing a fast purge. The most common need for this mode is to remove a liquid trap from within a vapor purge system. It is also used to remove sediments that may have collected in the line during a purge system failure.
 


 
Specifications
Max Ratings:
Teflon®:
2500psi @ 100°F
1500psi @ 220°F
*Ryton:
2500psi @ 220°F
1500psi @ 520°F
* DO NOT USE BELOW 200°F
Material:
All wetted and exposed parts are 316SS
Codes: Barstock, A479 - 316, A276-316; Cast, ASTM-A743 CF3M, ASTM-A-351 CF3M, A 276-316.
Design Codes:
ANSI B31.1, B16.5, NACE MR-01-75 (special order)
Spare Parts
Part Description:Part Number:Part Description:Part Number:
Flow Cartridge # 2
Flow Cartridge # 4
Flow Cartridge # 6
Flow Cartridge # 8
Ryton Face Seal (PRGM7 Only)
TSOFLOW2MZ
TSOFLOW4MZ
TSOFLOW6MZ
TSOFLOW8MZ
H80AMA02PZ
Viton® O-ring Cart. Seat Seal
Teflon® O-ring Cart. Seat Seal
Viton® O-ring Cart. Seal
Teflon® O-ring Cart. Seal
D71AAA05PZ
D70AAA05PZ
D71AAA06PZ
D70AAA06PZ

Viton® is a registered trademark of DuPont Dow Elastomers.
Teflon® is a registered trademark of DuPont.

Code Model
PRGM6 Single Purge Assembly
PRGM7 Double Purge Assembly
|Code Seals
|TT Teflon® / TFE O-Rings
|TV Teflon® / Viton® O-Rings
|RV Ryton / Viton® O-Rings
||Code Material
||SS Stainless Steel, 316
|||Code Connections
|||OutletInlet Description
|||AF1F2 Flanged Outlet to Manifold x 1/4" FNPT Inlet
||| PRGM6 Only
|||F2F2 1/4" FNPT Outlet (No Manifold) x 1/4" FNPT Inlet
|||||Code Flow Capsule Size
|||||#2 3.2 SCFH Air @ 10 Psi
|||||#4 1.0 SCFH Air @ 10 Psi
|||||#6 .40 SCFH Air @ 10 Psi
|||||#8 .10 SCFH Air @ 10 Psi
||||||Code Gauges (optional) leave blank if not required
||||||3 0-16 KG/CM² Stainless Steel
||||||5 0-40 KG/CM² Stainless Steel
||||||7 0-200 Psi Stainless Steel
||||||8 0-1000 Psi Stainless Steel
|||||||Code Manifold (PRGM7 Only)
|||||||GP3FU GP3FU-T-SS 3-Valve Manifold
||||||||Code Options
||||||||CV Check Valve Stainless Steel
||||||||PRGM6 Only
||||||||MB Mounting Bracket Kit for 2" pipe
||||||||PRGM7 Only
||||||||F2 1/4" FNPT GP3FU Outlet (Flange Std.)
||||||||| 
 Model Number

 

免責(zé)聲明

  • 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡(luò)有限公司-化工儀器網(wǎng)合法擁有版權(quán)或有權(quán)使用的作品,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權(quán)使用作品的,應(yīng)在授權(quán)范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關(guān)法律責(zé)任。
  • 本網(wǎng)轉(zhuǎn)載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點(diǎn)和對其真實(shí)性負(fù)責(zé),不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個(gè)人從本網(wǎng)轉(zhuǎn)載時(shí),必須保留本網(wǎng)注明的作品第一來源,并自負(fù)版權(quán)等法律責(zé)任。
  • 如涉及作品內(nèi)容、版權(quán)等問題,請?jiān)谧髌钒l(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。
企業(yè)未開通此功能
詳詢客服 : 0571-87858618
麻阳| 喀什市| 临澧县| 无锡市| 齐齐哈尔市| 化德县| 临潭县| 德化县| 炉霍县| 民和| 江源县| 渝北区| 贡山| 康乐县| 临城县| 太保市| 葵青区| 塔城市| 同心县| 柳江县| 太康县| 万安县| 石家庄市| 安岳县| 台安县| 花莲县| 那坡县| 平乡县| 湘阴县| 乐都县| 扎兰屯市| 五指山市| 陵川县| 溧水县| 四会市| 威远县| 泸水县| 兖州市| 石河子市| 包头市| 崇文区|