ACREL Hospital Isolated Power Supply Application in Malaysia

來源:江蘇安科瑞電器制造有限公司   2020年11月07日 11:07  

ACREL Hospital Isolated Power Supply Application in Malaysia

 

AbstractWith the widespread application of electronic medical equipment in hospitals, the threat of leakage current to patients is becoming greater and greater, especially in places where life is critical. The patients are directly exposed to various electrodes and sensors during surgery or anesthesia. Inserted into the human body, even the slight leakage current may cause the patient to be electrocuted. In addition, some medical equipment is used to maintain the lives of critically ill patients. Once the equipment is powered off, it will also threaten the lives of patients. Therefore, for the electrical design of the special place of the hospital, the IT system should be used for power supply in strict accordance with national standards and regulations.This article introduces the application of Medical isolated power supply in Malaysia,

 

Keywords:Medical IT,Insulation monitor device,fault locator

0.:Project Overview

Malaysia I.E.D is located in SELANGOR DARUL EHSAN,the project is mainly used in island hospital in Malaysia,the products are used for 12 circuit insulation fault location for 3 sets hospital isolated power system,the related products are insulation monitor device AIM-M200,signal test generator ASG150,centralized alarm indicator AID150,insulation fault locator AIL150-8,AIL150-4 and leakage current transformer AKH-0.66P26.

 

 

 

 

  • Medical IT system Introduction

ACREL medical IT system insulation monitoring device and fault location system is suitable for hospital operating room, ICU (CCU) and other important places, and can provide a safe place for such continuous, reliable power solutions.

 

2.Power Supply Solution for Medical Locations

2.1ICU, CCU ward Distribution Solutions (GGF-I8G isolate electrical cabinet system diagram, for example)

    

Option I  without fault location function

 

Option II  with fault location function

NOTE: In the power distribution solutions of intensive care unit , AID series centralized alarm and display device should be installed in the nurses 'station, the hospital staff of nurses' station monitor the Operating status of each isolated power system

 

Operating Room Distribution Solutions (GGF-O8G isolate electrical cabinet system diagram, for example)

 

Option I  without insulation fault location function

Note: 1. In the operating room power distribution solutions, AID series of external alarm and display device should be installed on the intelligence panel inside the operating room, or next to the intelligence panel (wall mounted installation). During surgery, the medical staff monitor the health of isolated power system.

2. In the scheme with insulation fault location function,if the number of located channels  is more than eight,two sets of AIL150 locator can be used. The combination can be AIL150-8  and AIL150-4 (up to 12 channels), or AIL150 -8 and AIL150-8 (up to 16 channels).

 

 

 

3.Typical wiring diagram

 

4. Introduction of 7-Piece Medical IT

Product name and type

Product picture

Description

AITR series medical isolation transformer

 

AITR series isolation transformer is specially used in medical IT system. The windings are treated with double insulation and have electrostatic shielding layer, which reduces electromagnetic interference between windings. The PT100 temperature sensor is installed in the wire bag to monitor the temperature of transformer. The whole body is treated with vacuum invasion paint, which increases mechanical strength and corrosion resistance. The product has good temperature rise performance and very low noise.

AIM-M200 medical intelligent insulation monitoring instrument

 

AIM-M200 medical intelligent insulation monitoring instrument adopts advanced microcontroller technology, which has high integration, compact size, convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for insulation monitoring of isolation power system in Class 2 medical locations such as operating room and intensive care unit.

AKH-0.66P26 current transformer

The AKH-0.66P26 type current transformer is the protective current transformer supporting the AIM-M200 insulation monitor, of which the maximum measurable current is 60A and the transformation ratio is 2000:1. The current transformer is directly fixed inside cabinet by screwing, and the secondary side is leaded out by the terminal, which is convenient to install and use.

AIL150-4/AIL150-8 insulation fault locator

AIL150-4/AIL150-8 insulation fault locator adopts high sensitivity transformer combined with high precision signal detecting circuit, which detects the signal imported into the system from ASG150 test signal generator and accurately locates the circuits which have insulation faults. AIL150-4 insulation fault locator can locate the insulation faults of 4 circuits, and the AIL150-8 insulation fault locator can locate the insulation faults of 8 circuits.

ASG150 test signal generator

The ASG150 test signal generator adopts 32-bit microprocessor chip and high-precision signal generation circuit to realize the generation of specific test signal. When the monitored IT system has insulation faults, it can start up and produce test signal in time, working with the insulation fault locator to realize insulation fault location.。

HDR-60-24 power module

HDR-60-24 direct-current power supply can provide 24V DC power supply simultaneously for AIM-M200 medical intelligent insulation monitoring instrument, ASG150 test signal generator, AIL150 series insulation fault locator and AID150 centralized alarm and display instrument. The power supply is of high capacity, stable voltage output and convenient installation, which can meet the power-supply requirements of the above-mentioned meters and is the recommended power supply product.

AID150 centralized alarm and display instrument

AID150 centralized alarm and display instrument adopts the LCD liquid crystal display and achieves data exchange with AIM-M200 medical intelligent insulation monitoring instrument through RS485 communication interface, which can real-time monitor multi-channel data of AIM-M200 medical intelligent insulation monitoring instrument.

 

5. On site Photos

 

 

 

Bibliography

1、IT System Insulation Monitoring Device and Fault Location System of Acrel.

2、IEC60354-7-710,Electrical installations of buildings-Part 7-710:Requirements for special installations or locations - Medical locations.

免責(zé)聲明

  • 凡本網(wǎng)注明“來源:化工儀器網(wǎng)”的所有作品,均為浙江興旺寶明通網(wǎng)絡(luò)有限公司-化工儀器網(wǎng)合法擁有版權(quán)或有權(quán)使用的作品,未經(jīng)本網(wǎng)授權(quán)不得轉(zhuǎn)載、摘編或利用其它方式使用上述作品。已經(jīng)本網(wǎng)授權(quán)使用作品的,應(yīng)在授權(quán)范圍內(nèi)使用,并注明“來源:化工儀器網(wǎng)”。違反上述聲明者,本網(wǎng)將追究其相關(guān)法律責(zé)任。
  • 本網(wǎng)轉(zhuǎn)載并注明自其他來源(非化工儀器網(wǎng))的作品,目的在于傳遞更多信息,并不代表本網(wǎng)贊同其觀點(diǎn)和對(duì)其真實(shí)性負(fù)責(zé),不承擔(dān)此類作品侵權(quán)行為的直接責(zé)任及連帶責(zé)任。其他媒體、網(wǎng)站或個(gè)人從本網(wǎng)轉(zhuǎn)載時(shí),必須保留本網(wǎng)注明的作品第一來源,并自負(fù)版權(quán)等法律責(zé)任。
  • 如涉及作品內(nèi)容、版權(quán)等問題,請(qǐng)?jiān)谧髌钒l(fā)表之日起一周內(nèi)與本網(wǎng)聯(lián)系,否則視為放棄相關(guān)權(quán)利。
企業(yè)未開通此功能
詳詢客服 : 0571-87858618
武山县| 涞水县| 嘉善县| 威远县| 库尔勒市| 拉孜县| 富川| 德保县| 营口市| 洱源县| 建湖县| 固原市| 稻城县| 广平县| 富源县| 玉环县| 留坝县| 航空| 建始县| 石门县| 兰州市| 洛川县| 曲靖市| 墨竹工卡县| 通州市| 三门县| 额济纳旗| 锡林郭勒盟| 木兰县| 华安县| 阿巴嘎旗| 蒲江县| 洛阳市| 四平市| 石家庄市| 循化| 东乡县| 淮南市| 古蔺县| 宜兰县| 兖州市|