DC Energy Meter Application in Bangladesh
Acrel Rebecca
Abstract: This article introduces the application of Acrel DC meters in POWERCOM company
in Bangladesh. It is mainly used in photovoltaic DC cabinets to measure the output current and voltage of the combiner box, and collect switch signals at the power distribution site. The device has an RS485 interface to upload the measured and collected data and equipment status.
Power Control&Management-POWERCOM is located in Bangladesh and is one of the largest energy companies in the country. Mainly used DC multi-function meter PZ72L-DE/CKJ and shunt, used to measure the output current and voltage of the combiner box, and collect the status of the switch.
PZ series intelligent DC energy meter is designed for applications such as DC panels, solar power, telecommunications base stations, and charging posts.
This series of instruments can measure voltage, current, power, forward and reverse power in DC system. It can be used for local display, and connected with industrial control equipment, computers, form a measurement and control system. And it has a variety of external excuse functions for the user to choose: RS485 communication interface, Modbus-RTU protocol, relay alarm output, digital input/output. According to different requirements, through the instrument panel keys, you can set the ratio, communication parameters.
The product meets the relevant technical requirements of the standard Q/GDW1825-2013 DC power meter specification, GB/T29318-2012 Non-vehicle charging electric energy metering for electric vehicles, Q/GDW364-2009 Single-phase energy meter specification.
3.1 Model description

3.2 Technical features

3.3 Product functions

In photovoltaic systems, the safety of the power generation system is very important. As an advanced intelligent and digital front-end collection component, PZ series meters have been widely used in DC screens, solar power supply, telecommunication base stations, charging piles and other occasions. It can realize real-time monitoring of the electrical parameters of the power generation loop, not only can display the power generation status of the loop, but also has a network communication function, and can form a power monitoring system with a serial server, a computer, etc. The system realizes the analysis and processing of the collected data, displays the operating status of the photovoltaic system in real time, provides a true and reliable basis for the project to solve the electricity problem, and has achieved good corporate benefits.